Mining Transformer Series

The Mining Explosion-proof AC Mobile Substation

The Mining Explosion-proof AC Mobile Substation is the mobile complete device consisting of the Dry-type Transformer for Mining Explosion-proof AC Mobile Substation, Permanent Magnet High-voltage Vacuum Switch for KBG series Mining Explosion-proof AC mobile Substation and Low-voltage Protection Box for BXB series Mining Explosion-proof Mobile substation. It is applicable for coal mines with high humility, with a mixture of gas and coal dust, and with explosion hazard, and provides power supply for VFD.

  • Model Meaning:




    Technical Parameters:

    Performance Parameters of The Mining Dry-type Transformer for Explosion-proof AC Mobile Substation with Primary Rated Voltage of 6kV


    Rated Capacity 

    (kVA)

    Voltage Combination (kV)

    Connection 

    Unit 

    Symbol

    Loss

    Impedance Voltage (%)

    No-Load Current (%)

    Primary Voltage

    Secondary Voltage

    No Load

    Load

    1250

    6
    (+10%,+5%,0,-5%)

    2x1.905

    Dy11d0

    3100

    7400

    8

    1.1

    1600

    3680

    8950

    8

    1

    2000

    4180

    10600

    8

    1

    2500

    5100

    12200

    8

    0.8

    3150

    6800

    13500

    8

    0.8

    Performance parameters of dry transformer for explosion-proof AC mobile substation for mining with primary 

    Performance parameters of The Mining Dry-Type Transformer for Explosion-proof AC Mobile Substation with Primary Rated Voltage of 10kV

    Rated Capacity (kVA)

    Voltage Combination (kV)

    Connection 

    Unit 

    Symbol

    Loss

    Impedance Voltage (%)

    No-Load Current (%)

    Primary Voltage

    Secondary 

    Voltage

    No Load

    Load

    1250

    10
    (+10%,+5%,0,-5%)

    2x1.905

    Dy11d0

    3400

    8380

    8

    1.1

    1600

    3950

    9750

    8

    1

    2000

    4680

    11200

    8

    1

    2500

    5400

    12400

    8

    0.8

    3150

    7000

    13700

    8

    0.8

    rated voltage of 6kV
    Performance parameters of dry transformer for explosion-proof AC mobile substation for mining with primary 
    rated voltage of 6kV
  •  

    Serial No.

    Model

    Length
    mm

    Width
    mm

    Height
    mm

    Weight
    kg

    Model

    Length
    mm

    Width
    mm

    Height
    mm

    Weight
    kg

    1

    KBZSGZY-1250/6/2x1.905

    4862

    1055

    1605

    8890

    KBZSGZY-1250/10/2x1.905

    4862

    1040

    1650

    8695

    2

    KBZSGZY-1600/6/2x1.905

    4932

    1060

    1690

    9675

    KBZSGZY-1600/10/2x1.905

    4932

    1100

    1705

    9185

    3

    KBZSGZY-2000/6/2x1.905

    5022

    1110

    1795

    10950

    KBZSGZY-2000/10/2x1.905

    5012

    1100

    1865

    11000

    4

    KBZSGZY-2500/6/2x1.905

    5252

    1160

    1855

    12670

    KBZSGZY-2500/10/2x1.905

    5222

    1180

    1920

    12805

    5

    KBZSGZY-3150/6/2x1.905

    5782

    1270

    1920

    15765

    KBZSGZY-3150/10/2x1.905

    5952

    1290

    1920

    16025

    I
    n case of any change in the external dimensions and weight provided in the instructions due to technical improvement, 
    the actual product shall prevail.
  • 1. Low No-load Losses

    Made of high-quality, high magnetically conductive, low-loss, cold-rolled grain-oriented silicon steel sheet.  Using a 45° fully-beveled seam and multi-stage step stacking structure, which effectively reduces no-load losses, no-load current and noise.

    2. Low Noise

    The noise is from the iron core, and is transferred to the surrounding through the housing. The connection joints are added with silicon sheet, which cuts off the noise spreading approach.

    3. Light Weight and Small Volume

    4. The Mobile Substation is explosion-proof and damp-proof.

    5. The Moble Substation has a perfect overload, short circuit and leakage protection. There is an electrical interlock or mechanical interlock device between the high- and low-voltage switches or between a high-voltage switch and a circuit breaker of the upper level.

    6. Energy Conservation and Environmental Protection

    1) Adopt a Nomex paper-wrapped line with insulation grade C that is imported from American DuPont Company. The product is air insulation and cooling. It has no pollution on the environment, and it has long service life; it can be decomposed for recovery after the service life ends;

    2) The high-quality 30Q130 cold-rolled oriented silicon steel sheet and oxygen-free copper conductor are adopted, so that the actual total loss is lower than that of the other similar products.It saves the energy, and lowers noise. The iron core surface is applied with the high-temperature-resistant rust-proof and damp-proof paint, Grade H insulation material is adopted for the iron core insulator, and there is no damage after operation at high temperature for a long term.

  • 1.The elevation shall not exceed 1,000m;

    2.Ambient temperature    Maximum temperature                              +40℃/104°F

                                            Maximum daily average temperature        +30℃/86°F

                                            Maximum annual average temperature     +20℃/68°F

                                            Minimum temperature                                -5℃/23°F

    3.The relative humidity shall not exceed 95% (at +25 ℃/77°F)

    4.Mines with a mixture of methane gas and coal dust, and a risk of explosion;

    5.Places without strong bump and vibration and with inclination from the vertical plane not exceeding 15°;

    6.No sufficient gas or vapour to cause metals corrosion or insulation damage;

    7.Places without dripping;

    8.The waveform of the supply voltage is similar to the sine wave;

    9.The three-phase supply voltage is approximately symmetrical.


Contact information

Submit your inquiry
Name:
Your message:
Phone:
E-Mail:
Company:
Name:
Country:
   

Your local Huaxin Sales Team

  • NameKai Wang
  • Address813 46th Street East, Saskatoon, Saskatchewan S7K 0X1, Canada
  • PhoneChina:15234310529,Canada:+1 (306) 713-2408
  • FaxChina:+86 (0)353-4909788
Close
Submit your inquiry
Name:
Your message:
Phone:
E-Mail:
Company:
Name:
Country:
   

Your local Huaxin Service Team

  • NameKai Wang
  • Address 813 46th Street East, Saskatoon, Saskatchewan S7K 0X1, Canada
  • PhoneChina:15234310529,Canada:+1 (306) 713-2408
  • FaxChina:+86 (0)353-4909788
Close
Submit your inquiry
Name:
Your message:
Phone:
E-Mail:
Company:
Name:
Country:
   

Your local Huaxin Cooperation Team

  • NameKai Wang
  • Address813 46th Street East, Saskatoon, Saskatchewan S7K 0X1, Canada
  • PhoneChina:15234310529, Canada:+1 (306) 713-2408
  • FaxChina:+86 (0)353-4909788
Close

©1996-2017 晋ICP备07500050号 Huaxin Copyright 

©2016-2017 晋ICP备07500050号 Huaxin Copyright